GATE 2020 Agricultural Engineering question: Saturated steam at 121 °C is used to sterilize pineapple juice by direct steam…
Saturated steam at 121 °C is used to sterilize pineapple juice by direct steam injection. The initial temperature of the juice is 80 °C and after sterilization, the blend of diluted juice exits the sterilizer at 95 °C. The enthalpy values of steam and condensate water are given in Table below. Specific heat capacity of the juice is 3.9 kJ kg °C. Assuming no energy loss to the surroundings in the process of sterilization, the ratio of juice sterilized to steam utilized is
| Temperature (°C) | Condensate water (kJ kg) | Saturated steam (kJ kg) | Phase change (kJ kg) |
|---|---|---|---|
| 95 | 397.9 | 2668.1 | 2270.2 |
| 121 | 507.7 | 2707.1 | 2205.2 |
Show answer
Official answer: C