GATE 2020 Agricultural Engineering question: A water pumping system is driven by a horizontal axis multi-bladed wind turbine at a…
A water pumping system is driven by a horizontal axis multi-bladed wind turbine at a power coefficient (C) of 0.4. The total pumping head and discharge are 20 m and 15 L s, respectively. The mean wind velocity is 8 m s and the pump efficiency is 70%. The density of air and water are 1.2 and 1000 kg m, respectively. If the transmission efficiency from wind turbine to the pump is 90%, the required diameter of the wind turbine in m (round off to 2 decimal places) is ______.
Show answer
Official answer: 6.92 to 6.98