GATE 2020 Biomedical Engineering question: The tensile strength of a degradable suture used for a surgical procedure in the human…
The tensile strength of a degradable suture used for a surgical procedure in the human body is observed to decrease exponentially from its original strength by 40% and 50% after 10 days and 20 days, respectively. The closest approximation of the time taken for the tensile strength to decay to 20% of its original value would be
Show answer
Official answer: D