GATE Assistant

Past questions › Biomedical Engineering › GATE 2020

GATE 2020 · BM · NAT · 2 marks · Signals and Systems › Impulse Response & Transfer Function

GATE 2020 Biomedical Engineering question: A cell is injected with a current i(t) = u(t) to produce a change in the intracellular…

A cell is injected with a current to produce a change in the intracellular membrane voltage . The cell-membrane is modeled as a linear system with impulse response . The cell membrane voltage output at 5 ms is ____________ mV.

Use V/s; = 3 ms.

Show answer

Official answer: -84 to -81

Practise this question with exam-style marking

Discussion

No discussion yet.