GATE 2020 Electrical Engineering question: Bus 1 with voltage magnitude V 1 = 1.1 pu is sending reactive power Q 12 towards bus 2…
Bus 1 with voltage magnitude pu is sending reactive power towards bus 2 with voltage magnitude pu through a lossless transmission line of reactance . Keeping the voltage at bus 2 fixed at 1 pu, magnitude of voltage at bus 1 is changed, so that the reactive power sent from bus 1 is increased by 20%. Real power flow through the line under both the conditions is zero. The new value of the voltage magnitude, , in pu (rounded off to 2 decimal places), at bus 1 is ______.

Show answer
Official answer: 1.11 to 1.13