GATE Assistant

Past questions › Instrumentation Engineering › GATE 2020

GATE 2020 · IN · NAT · 2 marks · Sensors & Industrial Instrumentation › Resistive & Capacitive Transducers

GATE 2020 Instrumentation Engineering question: A metallic strain gauge of resistance R x with a gauge factor of 2 is bonded to a…

A metallic strain gauge of resistance with a gauge factor of 2 is bonded to a structure made of a metal with modulus of elasticity of 200 GN/m. The value of is 1 k when no stress is applied. is a part of a quarter bridge with three identical fixed resistors of 1 k each. The bridge is excited from a DC voltage of 4 V. The structure is subjected to a stress of 100 MN/m. Magnitude of the output of the bridge (in mV, rounded off to two decimal places) is ______

Show answer

Official answer: 0.95 to 1.05

Practise this question with exam-style marking

Discussion

No discussion yet.

Join the discussion