GATE 2021 set2 Civil Engineering question: In a three-phase signal system design for a four-leg intersection, the critical flow…
In a three-phase signal system design for a four-leg intersection, the critical flow ratios for each phase are 0.18, 0.32, and 0.22. The total loss time in each of the phases is 2 s. As per Webster’s formula, the optimal cycle length (in s, round off to the nearest integer) is ________
Show answer
Official answer: 48 to 52