GATE 2021 Chemical Engineering question: A distillation column handling a binary mixture of A and B is operating at total reflux.…
A distillation column handling a binary mixture of A and B is operating at total reflux. It has two ideal stages including the reboiler. The mole fraction of the more volatile component in the residue ( ) is 0.1. The average relative volatility is 4. The mole fraction of A in the distillate () is ______________ (round off to 2 decimal places).
Show answer
Official answer: 0.63 to 0.65