GATE Assistant

Past questions › Electrical Engineering › GATE 2021

GATE 2021 · EE · NAT · 2 marks · Control Systems › Time-Domain Analysis

GATE 2021 Electrical Engineering question: In the given figure, plant G p(s)= 2.2 (1+0.1s)(1+0.4s)(1+1.2s) and compensator G c(s)=K…

In the given figure, plant and compensator . The external disturbance input is D(s). It is desired that when the disturbance is a unit step, the steady-state error should not exceed 0.1 unit. The minimum value of K is ________.
(Round off to 2 decimal places.)

figure

Show answer

Official answer: 9.5 to 9.6

Practise this question with exam-style marking

Discussion

No discussion yet.