GATE Assistant

Past questions › Instrumentation Engineering › GATE 2021

GATE 2021 · IN · MCQ · 1 mark · Measurements › Measurement Systems & Error Analysis

GATE 2021 Instrumentation Engineering question: In an ac main, the rms voltage V ac , rms current I ac and power W ac are measured as: V…

In an ac main, the rms voltage , rms current and power are measured as: V 1%, A 1% and W 2% (errors are with respect to readings). The percentage error in calculating the power factor using these readings is

  1. (A)

    1%

  2. (B)

    2%

  3. (C)

    3%

  4. (D)

    4%

Show answer

Official answer: D