GATE 2021 Instrumentation Engineering question: A strain gage having nominal resistance of 1000 has a gage factor of 2.5. If the strain…
A strain gage having nominal resistance of 1000 has a gage factor of 2.5. If the strain applied to the gage is 100 µm/m, its resistance in ohm will change to ____________ (rounded off to two decimal places).
Show answer
Official answer: 1000.25