GATE 2021 Production and Industrial Engineering question: Heat is being removed from a refrigerator at a rate of 300 kJ/min to maintain its inside…
Heat is being removed from a refrigerator at a rate of 300 kJ/min to maintain its inside temperature at 2 °C. If the input power to the refrigerator is 2 kW, the coefficient of performance of the refrigerator is __________.
[round off to one decimal place]
Show answer
Official answer: 2.4 to 2.6