GATE Assistant

Past questions › Engineering Sciences › GATE 2021 TF

GATE 2021 TF · XE · NAT · 2 marks · Textile Engineering and Fibre Science (XE9) › Printing & Finishing

GATE 2021 TF Engineering Sciences question: A counter-flow heat exchanger is attached to a stenter for waste heat recovery. Consider…

A counter-flow heat exchanger is attached to a stenter for waste heat recovery.

figure

Consider the following data:

Ambient temperature : 30 °C
Temperature of exhaust from stenter : 150 °C
Temperature of exhaust at exit of heat exchanger : 100 °C
Specific heat of exhaust : 0.42 kcal·deg·kg
Specific heat of air : 0.24 kcal·deg·kg

At steady state, if the mass flow rates of the exhaust gas and the incoming air are the same, assuming heat loss as zero, the temperature (°C) of the air at the exit of the heat exchanger (towards the stenter), (rounded off to one decimal place), is ________.

Show answer

Official answer: 117 to 118

Practise this question with exam-style marking

Discussion

No discussion yet.

Join the discussion