For a refrigeration cycle, the ratio of actual COP to the COP of a reversible refrigerator operating between the same temperature limits is 0.8. The condenser and evaporator temperatures are 51°C and −30°C, respectively. If the cooling capacity of the plant is 2.4 kW, then the power input to the refrigerator is:

(COP: Coefficient of Performance)

  1. (A)

    1.00 kW

  2. (B)

    1.33 kW

  3. (C)

    1.25 kW

  4. (D)

    2.08 kW

Show answer

Official answer: A