GATE Assistant

Past questions › Engineering Sciences › GATE 2021

GATE 2021 · XE · NAT · 2 marks · Thermodynamics (XE4) › Mixtures of Ideal Gases & Psychrometry

GATE 2021 Engineering Sciences question: A mixture of air and water vapour enters a steady-flow adiabatic saturator at 50°C and…

A mixture of air and water vapour enters a steady-flow adiabatic saturator at 50°C and 100 kPa. It leaves the saturator in a completely saturated state at temperature of 25°C and pressure of 100 kPa. Liquid water enters the saturator at 25°C. If air is considered to be an ideal gas, with constant specific heat capacity, the relative humidity of the air entering the saturator is _______ % (1 decimal place).

Use the following data:

at 25°C = 104.87 kJ/kg, = 2547.17 kJ/kg, =3.161 kPa

at 50°C = 209.31 kJ/kg, = 2592.06 kJ/kg, =12.335 kPa

Specific heat capacity of air at constant pressure =1.005 kJ/(kgK)

Show answer

Official answer: 12.1 to 13

Practise this question with exam-style marking

Discussion

No discussion yet.

Join the discussion