GATE Assistant

Past questions › Biotechnology › GATE 2022

GATE 2022 · BT · NAT · 2 marks · Fundamentals of Biological Engineering › Media Formulation & Sterilization

GATE 2022 Biotechnology question: A pilot sterilization was carried out in a vessel containing 100 m 3 medium with an…

A pilot sterilization was carried out in a vessel containing 100 m medium with an initial spore concentration of spores/ml. The accepted level of contamination after sterilization is 1 spore in the entire vessel. The specific death rate constant for the spore is 2 min at 121 ˚C. Assuming no death takes place during the heating and cooling cycles, the holding time at 121 ˚C (rounded off to nearest integer) is _____________min.

Show answer

Official answer: 17 to 19

Practise this question with exam-style marking

Discussion

No discussion yet.