GATE 2022 Chemical Engineering question: A perfectly insulated double pipe heat exchanger is operating at steady state. Saturated…

A perfectly insulated double pipe heat exchanger is operating at steady state. Saturated steam enters the inner pipe at 100 °C and leaves as saturated water at 100 °C. Cooling water enters the outer pipe at 75 °C and exits at 95 °C. The overall heat transfer coefficient is 1 kW m K and the heat transfer area is 1 m. The average specific heat capacity of water at constant pressure is 4.2 kJ kg K. The required cooling water flow rate is __________ kg s (rounded off to two decimal places).

Show answer

Official answer: 0.14 to 0.15