GATE Assistant

Past questions › Chemical Engineering › GATE 2022

GATE 2022 · CH · NAT · 2 marks · Instrumentation & Process Control › Measurement of Process Variables

GATE 2022 Chemical Engineering question: A venturi meter (venturi coefficient, C v = 0.98) is connected to a pipe of inner…

A venturi meter (venturi coefficient, ) is connected to a pipe of inner diameter 50 mm. Water (density 1000 kg m) is flowing through the pipe. The pressure-drop measured across the venturi meter is 50 kPa. If the venturi throat diameter is 20 mm, the estimated flow rate of water is _______ m s (rounded off to two decimal places).

Show answer

Official answer: 3.1 to 3.17

Practise this question with exam-style marking