During open-heart surgery, a patient’s blood is cooled down to 25 °C from 37 °C using a concentric tube counter-flow heat exchanger. Water enters the heat exchanger at 4 °C and leaves at 18 °C. Blood flow rate during the surgery is 5 L/minute.

Use the following fluid properties:

Fluid Density (kg/m) Specific heat (J/kg-K)
Blood 1050 3740
Water 1000 4200

Effectiveness of the heat exchanger is _________ (round off to 2 decimal places).

Show answer

Official answer: 0.4 to 0.44