GATE 2023 Agricultural Engineering question: Discharge from a centrifugal pump operating at 1000 rpm with a total head of 30 m is 300…

Discharge from a centrifugal pump operating at 1000 rpm with a total head of 30 m is 300 L min. The pump efficiency is 65%. If speed of the pump is increased to 1200 rpm, the power required to operate the pump in kW is _______________ (rounded off to 2 decimal places).

Consider acceleration due to gravity = 9.81 m s.

Show answer

Official answer: 3.9 to 4