GATE 2023 · BM · MCQ · 2 marks · Measurements and Control Systems › SI Units, Errors & Uncertainty

GATE 2023 Biomedical Engineering question: A 20 mV DC signal has been superimposed with a 10 mV RMS band-limited Gaussian noise…

A 20 mV DC signal has been superimposed with a 10 mV RMS band-limited Gaussian noise with a flat spectrum upto 5 kHz. If an integrating voltmeter is used to measure this DC signal, what is the minimum averaging time (in seconds) required to yield a 99 % accurate result with 95 % certainty?

  1. (A)

    0.1

  2. (B)

    1.0

  3. (C)

    5.0

  4. (D)

    10.0

Show answer

Official answer: B