GATE Assistant

Past questions › Biomedical Engineering › GATE 2023

GATE 2023 · BM · NAT · 2 marks · Sensors and Bioinstrumentation › Sensor Types & Signal Conditioning

GATE 2023 Biomedical Engineering question: A Wheatstone bridge strain gauge transducer is constructed on a diaphragm in such a way…

A Wheatstone bridge strain gauge transducer is constructed on a diaphragm in such a way that when a force is applied on the diaphragm, the resistors R and R will be in compression, and the resistors R and R will be in tension.

The bridge excitation voltage (E) is 10 Volts. If all the resistors have a resistance of 200 Ω in the absence of any force, and each resistance changes by 20 Ω upon application of a force, what is the output voltage V (in Volts) from the Wheatstone bridge? (Round off your answer to the nearest integer.)

figure

Show answer

Official answer: -1 or 1

Practise this question with exam-style marking

Discussion

No discussion yet.