A 50 Hz, 275 kV line of length 400 km has the following parameters:

Resistance, /km;

Inductance, mH /km;

Capacitance, F/km;

The line is represented by the nominal- model. With the magnitudes of the sending end and the receiving end voltages of the line (denoted by and , respectively) maintained at 275 kV, the phase angle difference () between and required for maximum possible active power to be delivered to the receiving end, in degree is ______________ (Round off to 2 decimal places).

Show answer

Official answer: 83 to 84