GATE 2023 Environmental Science and Engineering question: An aeration tank needs to be installed for the removal of VOC from water, where the…
An aeration tank needs to be installed for the removal of VOC from water, where the required rate of flow of water through the aeration tank is 180,000 m/d. Permissible limit of VOC in the water is 12 µg/L. The saturation concentration of VOC is 5 µg/L and gas transfer rate constant is 0.40 per second at 25 °C. The initial concentration of VOC in the water is 33 µg/L. The volume of the aeration tank to satisfy the permissible limit of VOC at 25 °C is ________________(in m, rounded off to two decimal places).
Show answer
Official answer: 7.1 to 7.3