GATE Assistant

Past questions › Engineering Sciences › GATE 2023

GATE 2023 · XE · NAT · 2 marks · Thermodynamics (XE4) › Second Law of Thermodynamics

GATE 2023 Engineering Sciences question: An office uses a heat pump to receive 500 kJ/day heat in winter to maintain its…

An office uses a heat pump to receive 500 kJ/day heat in winter to maintain its temperature at 300 K. The ambient temperature is 280 K. If the COP of the heat pump is 60% of its theoretical maximum value, the ratio of actual work input to the minimum theoretical work input to the heat pump is ____________ (rounded off to one decimal place).

Show answer

Official answer: 1.6 to 1.8

Practise this question with exam-style marking

Discussion