GATE 2024 Mining Engineering question: Data for a centrifugal pump discharging water from a sump to the surface are given. -…
Data for a centrifugal pump discharging water from a sump to the surface are given.
- Head, m: 180
- Discharge rate, m/hr: 320
- Operating hours per day for 270 days in a year: 14
- Operating hours per day for remaining 95 days: 20
- Overall efficiency of the pumping system: 0.70
- Specific weight of mine water, kN/m: 10.20
The annual electrical power consumption in GWh, due to pumping operation, is ______. (round off up to 2 decimals)
Show answer
Official answer: 1.31 to 1.33