GATE Assistant

Past questions › Mining Engineering › GATE 2024

GATE 2024 · MN · NAT · 2 marks · Mining Methods and Machinery › Hoisting Systems & Pumps

GATE 2024 Mining Engineering question: Data for a centrifugal pump discharging water from a sump to the surface are given. -…

Data for a centrifugal pump discharging water from a sump to the surface are given.

  • Head, m: 180
  • Discharge rate, m/hr: 320
  • Operating hours per day for 270 days in a year: 14
  • Operating hours per day for remaining 95 days: 20
  • Overall efficiency of the pumping system: 0.70
  • Specific weight of mine water, kN/m: 10.20

The annual electrical power consumption in GWh, due to pumping operation, is ______. (round off up to 2 decimals)

Show answer

Official answer: 1.31 to 1.33

Practise this question with exam-style marking

Discussion

No discussion yet.

Join the discussion