GATE 2024 Engineering Sciences question: A tubular bowl centrifuge is used to separate an aqueous phase from an oil phase. The…
A tubular bowl centrifuge is used to separate an aqueous phase from an oil phase. The radii of outlets of the light and heavy liquids are set at 4.5 cm and 4.6 cm, respectively. The radius in cm of the neutral zone in the centrifuge is_____________ (round off to 2 decimal places). Assume the density of the aqueous phase is 950 kg.m and that of oil is 900 kg.m.
Show answer
Official answer: 6.05 to 6.18