GATE Assistant

Past questions › Agricultural Engineering › GATE 2025

GATE 2025 · AG · NAT · 2 marks · Dairy and Food Engineering › Heat Transfer in Food Processing

GATE 2025 Agricultural Engineering question: Milk enters at 25 °C through inner pipe of a concentric double pipe heat exchanger. Hot…

Milk enters at 25 °C through inner pipe of a concentric double pipe heat exchanger. Hot water enters at 82.5 °C and flows countercurrently (flow rate = 1.2 kg.s) through the annular region. The diameter of inner pipe, length of the pipe and average overall heat transfer coefficient are 60 mm, 6 m, and 2100 W.m.K, respectively. The average values of specific heat capacity of water and milk are 4.18 kJ.kg.K and 3.95 kJ.kg.K, respectively. The effectiveness of the heat exchanger is 0.572 and the NTU is 1.01. Assuming the steady-state condition and considering as 3.14, the temperature of hot water at exit of the pipe is _________ C. (Rounded off to 1 decimal place)

Show answer

Official answer: 66.9 to 67.5

Practise this question with exam-style marking

Discussion

No discussion yet.

Join the discussion