GATE 2025 set2 Civil Engineering question: A 60 cm diameter well completely penetrates a confined aquifer of permeability 5 10 -4…
A 60 cm diameter well completely penetrates a confined aquifer of permeability m/s. The length of the strainer (spanning the entire thickness of the aquifer) is 10 m. The drawdown at the well under steady state pumping is 1.0 m. Assume that the radius of influence for this pumping is 300 m.
The discharge from the well (in litres per minute) is ______ (round off to the nearest integer).
Show answer
Official answer: 271 to 273