A metallic strain-gauge (SG) with resistance is connected as shown in the figure, where , , represent the lead wire resistances. The SG has a gauge factor of 2 and nominal resistance of 125 . When the SG is subjected to a tensile strain of , the resulting change in is . The value is measured as . The and are the equivalent resistances measured between the terminals 1 and 2, and terminals 2 and 3, respectively.

If , and , the measured value of tensile strain is ___ (rounded off to two decimal places).

figure

Show answer

Official answer: 1.75 to 1.85