GATE 2025 Instrumentation Engineering question: Consider an AC bridge shown in the figure with R = 300 Ω, R1 = 1000 Ω, R2 = 500 Ω, L =…
Consider an AC bridge shown in the figure with R = 300 Ω, R1 = 1000 Ω, R2 = 500 Ω, L = 30 mH, and a detector D. At the bridge balance condition, the frequency of the excitation source is __________ kHz (rounded off to two decimal places).

Show answer
Official answer: 1.55 to 1.65