GATE 2025 Mining Engineering question: In a bord and pillar panel, a square pillar of size 35 m × 35 m (centre to centre) is…

In a bord and pillar panel, a square pillar of size 35 m × 35 m (centre to centre) is extracted to form four equal square-shaped stooks as shown. The width of each gallery and crosscut is 5 m. The height of the working seam is 3 m. The reduction in safety factor after pillar splitting by using Bieniawski’s pillar strength formula, in %, is_____ (rounded off to 2 decimal places)

figure

Bieniawski’s pillar strength formula, ; where, = strength of 0.9 m of coal block, = pillar width and = mining height

Show answer

Official answer: 63 to 66