A fixed control volume has four one-dimensional boundary sections (1, 2, 3, and 4). For a steady flow inside the control volume, the flow properties at each section are tabulated below:

Boundary Section Type Density (kg/m) Surface Normal Velocity (m/s) Cross-sectional Area (m) Specific Energy (J/kg)
1 Inlet 1000 10 0.5 200
2 Inlet 1000 2 3.0 50
3 Outlet 1000 5 1.0 100
4 Outlet 1000 4 1.5 80

The rate of change of energy of the system which occupies the control volume at this instant is J/s. The value of (rounded off to 2 decimal places) is ________

Show answer

Official answer: -0.32

Practise this question with exam-style marking