GATE Assistant

Past questions › Architecture and Planning › GATE 2026

GATE 2026 · AR · NAT · 2 marks · Part B1: Architecture › Passive Design & Building Energy

GATE 2026 Architecture and Planning question: A building facade has 48 m 2 of glazing area. The properties of glass used in the…

A building facade has 48 m of glazing area. The properties of glass used in the glazing are as follows:

U-value: 5.2 W/m °C

Light to Solar Gain (LSG) Ratio: 1.5

Visual Light Transmittance (VLT): 0.6

The average solar radiation on the glazing is 400 W/m. If the outdoor and indoor set point temperatures are 35 °C and 20 °C, respectively, then the total heat gain (in kW) through the glazing by conduction and radiation is _____________ (rounded off to two decimal places).

Show answer

Official answer: 10 to 13

Practise this question with exam-style marking

Discussion

No discussion yet.

Join the discussion