GATE Assistant

Past questions › Biomedical Engineering › GATE 2026

GATE 2026 · BM · MSQ · 2 marks · Analog and Digital Electronics › Instrumentation Amplifiers & Filters

GATE 2026 Biomedical Engineering question: The circuit shown below is used as an instrumentation amplifier. Among the resistors…

The circuit shown below is used as an instrumentation amplifier. Among the resistors used in the input stage, the value of resistance of one of the resistors () is slightly mismatched from that of the rest of the resistors (). Assume all operational amplifiers are ideal.

Which of the following statements is/are true?

figure

  1. (A)

    The resistance mismatch introduces a gain error

  2. (B)

    The resistance mismatch degrades the common mode rejection ratio (CMRR)

  3. (C)

    The resistance mismatch introduces an offset error

  4. (D)

    is not sensitive to any resistance mismatch

Show answer

Official answer: A,B

Practise this question with exam-style marking

Discussion

No discussion yet.

Join the discussion