GATE 2026 Instrumentation Engineering question: A digital counter increments its count every 0.1 µs. The counter is used in an…
A digital counter increments its count every 0.1 µs. The counter is used in an instrument to measure frequency. The counter is operated for one period of the input signal to the instrument to measure its frequency. The input signal is approximately at 100 kHz. The maximum error in the measured frequency is _____ kHz. (rounded off to the nearest integer)
Show answer
Official answer: 1