GATE 2020 Mining Engineering question: A mine gallery is supported by regularly placed roof bolts of 100 kN allowable pull…
A mine gallery is supported by regularly placed roof bolts of 100 kN allowable pull force per bolt, as shown below. Assuming unit weight of the immediate roof is 25 kN /m³, the factor of safety of the support system is _____ (round off to 2 decimal places).

Show answer
Official answer: 2.1 to 2.45