GATE 2021 Mining Engineering question: A 10 ml sample of wastewater is diluted with water having no BOD, to fill a 300 ml BOD…

A 10 ml sample of wastewater is diluted with water having no BOD, to fill a 300 ml BOD bottle. The initial DO of the diluted waste water is 9.0 mg/l. If the BOD of the waste water sample is 60 mg/l, the final DO of the diluted waste water in mg/l, is

  1. (A)

    5.0

  2. (B)

    6.0

  3. (C)

    7.0

  4. (D)

    8.0

Show answer

Official answer: C