GATE Assistant

Past questions › Mining Engineering › GATE 2023

GATE 2023 · MN · NAT · 2 marks · Surface Environment, Mine Ventilation and Underground Hazards › Ventilation Surveys & Networks

GATE 2023 Mining Engineering question: A fan installed in a mine ventilation system circulates 30 m 3/s of air to two districts…

A fan installed in a mine ventilation system circulates 30 m/s of air to two districts A and B as shown in Figure below. It is desired to increase the quantity of air by 20% in the district B using a booster fan in it. Assuming that the main fan pressure is unchanged, the pressure of the booster fan, in Pa, is_____.

[rounded off to 2 decimal places]

figure

Show answer

Official answer: 305 to 325

Practise this question with exam-style marking

Discussion

No discussion yet.

Join the discussion