GATE 2024 Mining Engineering question: In a development coal face, 12 holes are drilled and charged with explosive. Holes are…
In a development coal face, 12 holes are drilled and charged with explosive. Holes are initiated with electric delay detonators connected in series. The length of a detonator lead wire is 1.5 m. The length of the blasting cable is 120 m.
Data are as given:
- Resistance of each detonator: 1.48 Ω
- Resistance of lead wire: 0.04 Ω/m
- Resistance of one wire of the blasting cable: 0.009 Ω/m
The total resistance of the circuit in Ω, is ______. (round off up to 2 decimals)
Show answer
Official answer: 20.8 to 21.9