GATE 2026 Petroleum Engineering question: The upper limit of the scale of the dial reading for a given rotational oilfield…
The upper limit of the scale of the dial reading for a given rotational oilfield viscometer is 300. At the rotational rate of 100 RPM, the highest possible effective (apparent) viscosity measurable (in cP) is ________. (Rounded off to one decimal place)
[Given: 1 dial reading is equivalent to 5.11 dynes/cm or 0.511 Pa; 1 RPM = 1.703 s]
Show answer
Official answer: 880 to 920