GATE Assistant

Past questions › Petroleum Engineering › GATE 2026

GATE 2026 · PE · NAT · 2 marks · Oil and Gas Well Drilling Technology › Drilling Fluids

GATE 2026 Petroleum Engineering question: The upper limit of the scale of the dial reading for a given rotational oilfield…

The upper limit of the scale of the dial reading for a given rotational oilfield viscometer is 300. At the rotational rate of 100 RPM, the highest possible effective (apparent) viscosity measurable (in cP) is ________. (Rounded off to one decimal place)
[Given: 1 dial reading is equivalent to 5.11 dynes/cm or 0.511 Pa; 1 RPM = 1.703 s]

Show answer

Official answer: 880 to 920

Practise this question with exam-style marking